Flue gas measurement for chimney sweeps in Austria: limits under Art. 15a B-VG

In Austria, an agreement between the federal states under Art. 15a B-VG sets which values are measured when firing installations are inspected and which limits apply. The table for installations under 50 kW, the inspection intervals and how Kehrwerk applies the Austrian rules.

Chimney sweep on a roof in Vienna

What Germany calls a Schornsteinfeger, Austria calls a Rauchfangkehrer, and the rules for flue gas measurement differ too. Instead of the 1. BImSchV, the governing text is the agreement under Art. 15a B-VG on placing small firing appliances on the market and inspecting firing installations and CHP units. Each federal state publishes it, which keeps emission limits and measured values the same across Austria. This article shows what the agreement sets for the Austrian chimney sweep's flue gas measurement, and how Kehrwerk checks the Austrian values as you type.

The source is the publication of the agreement in the Tyrol state law gazette, LGBl. No. 42/2012. The binding text is the agreement and the state law that implements it.

Kehrwerk speaks Austrian

Set the country to Austria and the app checks under Art. 15a B-VG. Free forever for one person.

Download on the App StoreGet it on Google Play

Limits under 50 kW: Article 13

Article 13 (1) sets the emission limits and flue gas losses that installations with a rated heat output under 50 kW must not exceed. For liquid fuels:

  • Flue gas loss: 10 percent
  • Smoke number: 1
  • CO: 100 mg/m³, referenced to 3 percent oxygen

For gaseous fuels:

  • Firing installations: flue gas loss 10 percent, CO 100 mg/m³
  • Water heaters from 26 kW rated output: flue gas loss 14 percent, CO 200 mg/m³
  • CO referenced to 3 percent oxygen in both cases

For solid fuels, the value depends on how the appliance is fed:

  • hand-fed: flue gas loss 20 percent, CO 3,500 mg/m³
  • automatically fed: flue gas loss 19 percent, CO 1,500 mg/m³
  • CO referenced to 11 percent oxygen for biogenic and 6 percent for fossil fuels

Article 13 (2) sets separate values for installations burning non-standardised biogenic fuels at the first inspection. For installations from 50 kW, Article 14 refers to the Austrian Firing Installations Ordinance.

Austrian chimney sweep walking along a roof walkway between the chimneys of Viennese apartment buildings, the Karlskirche behind.
Austrian chimney sweeps work under the Art. 15a B-VG agreement.

What is measured: Article 18 (2)

In a simple inspection, Article 18 (2) requires: CO content, CO2 or O2 content, combustion air and flue gas temperatures, boiler temperature, draught in the flue and flue gas loss. Liquid fuel installations add the smoke number, CHP units add CO and NOx. Measurement takes place in the operating state the installation mostly runs in, primarily under the relevant ÖNORM standards.

The biggest difference from Germany is CO: Austria measures it on every fuel, including gas and oil.

How often installations are inspected

Under Article 18 (1), the simple inspection is due no later than four weeks after commissioning and then recurring:

  • at least every four years for gas installations under 26 kW,
  • every two years for installations under 50 kW and water heaters from 26 kW burning standardised biogenic or fossil fuels,
  • every year for non-standardised biogenic fuels, installations from 50 kW and CHP units.

Under Article 17 (1), room heaters among others are exempt from inspection unless the states provide otherwise.

CO, flue gas loss and smoke number, checked as you type

Kehrwerk shows the Austrian limit right under the field. Download it and measure without signing up.

Download on the App StoreGet it on Google Play

Assessment, inspection report and repair

For flue gas loss, Article 18 (3) treats the installation as fit if the rounded result does not exceed the limit. For CO and NOx, the assessed value taking the error limit of the method into account counts. Under Article 18 (4), an inspection report under Annex 2 is drawn up and handed to the operator, who keeps it at least until the next inspection.

If the limits are not met, Article 23 requires the installation to be repaired within eight weeks at most, with longer periods if the installation or a major component must be replaced. A new inspection follows within four weeks of the repair.

How Kehrwerk applies the Austrian rules

In Kehrwerk you set the country once for your business and every new site inherits it. It can be changed for individual sites. With Austria as the country, two things change: which fields the app asks for, and which limits it checks.

  • Fields under Article 18 (2): CO, oxygen, combustion air and flue gas temperature, boiler temperature, draught in the flue and flue gas loss.
  • Gas and oil under 50 kW: flue gas loss 10 percent and CO 100 mg/m³, and for oil the smoke number 1 on the mean of the three readings.
  • Solid fuels under 50 kW: the app asks whether the appliance is hand-fed or automatic, then checks 20 or 19 percent flue gas loss and 3,500 or 1,500 mg/m³ CO.
  • From 50 kW, Article 14 refers to the Firing Installations Ordinance. Kehrwerk records every value there and leaves the assessment to you.

CHP units are covered as well: fuel and output set the CO and NOx limits under Article 15, each at 5 percent oxygen, and liquid fuel units up to 0.25 MW fuel heat input add the Bosch smoke number.

Flue gas measurement: the analyser probe sits in the test port of the flue pipe, a hand holds the analyser.
In Austria, CO is measured on every fuel.

The protocol from the app

The Kehrwerk PDF names Art. 15a B-VG with the relevant article as the legal basis and shows each assessed value with its limit, met or exceeded. It is your measurement protocol for the office, with photos and the owner's signature. You issue the inspection report under state law as usual. The CSV has its own column for the assessment country, so a sheet with measurements from several countries stays unambiguous.

Just as in Germany, every keystroke is saved at once, the measurement stays on the phone, and you only need a signal to send it. In the vaulted cellar of an old Viennese apartment block, that is no small thing.

Free for chimney sweeps, with an office for businesses

Free forever on your own. Businesses: 39 euros a month plus 15 euros per seat, net, 14 days free.

Download on the App StoreGet it on Google Play
Which flue gas loss applies to a gas boiler in Austria?

For gas installations under 50 kW, 10 percent under Article 13 of the Art. 15a B-VG agreement. For water heaters from 26 kW the table gives 14 percent.

Is CO measured on gas and oil in Austria?

Yes. Article 18 (2) requires CO at every simple inspection, and the limit for gas and oil under 50 kW is 100 mg/m³ referenced to 3 percent oxygen.

How often is a gas boiler under 26 kW inspected?

At least every four years under Article 18 (1). Installations under 50 kW on standardised fuels are otherwise inspected every two years.

Does every federal state set different limits?

No. The emission limits come from the Art. 15a B-VG agreement, which every state publishes in the same wording. That is why Kehrwerk applies one Austrian rule set across all states.

How do I switch Kehrwerk to Austria?

Set the country to Austria in the business settings. New sites inherit it, and finished measurements keep the country they were assessed under.

Try Kehrwerk on your next reading.

The chimney sweep app for flue gas readings on site. Free forever for one person, no signup.

Download on the App StoreGet it on Google Play