Guides for chimney sweeps.

On flue gas readings, measurement records and the work on site, and how Kehrwerk helps with it. No legal advice.

Chimney sweep measuring flue gas in a boiler room

The chimney sweep app for flue gas measurement on site

Pick the appliance, type the values, see the limit, photo, signature, PDF. How an app captures the daily flue gas measurement in the boiler room, so nothing has to be typed up in the evening.

Read more
Wall-mounted gas boiler during a flue gas measurement

Flue gas loss limits under the 1. BImSchV: the table by kW

11, 10 or 9 percent: which flue gas loss limit applies to oil and gas firing depends on the rated heat output. The table from § 10, the exceptions and what else is limited during the measurement.

Read more
Screenshot: measurement with values entered

Guide: your first flue gas measurement with Kehrwerk, from install to PDF

Seven steps, about ten minutes the first time and two minutes per appliance after that. How to get from a freshly installed app to a finished measurement protocol as a PDF.

Read more
Flue gas analyser showing temperature and oxygen

Calculating flue gas loss: formula, factors and a worked example

Flue gas temperature, combustion air temperature, oxygen and two fuel factors: this is the flue gas loss formula as it stands in Annex 2 of the 1. BImSchV, and how to work it through on three examples.

Read more
Screenshot: measurement over the limit

Guide: how the limit warning works in Kehrwerk

Flue gas loss is checked as you type. What the app needs for it, what the warning looks like, and how a limit breach differs from a typing error.

Read more
Oil heating in a cellar during the smoke number test

Measuring the smoke number on oil heating: three readings, the mean, oil derivatives

Three filter papers, one mean, one visual check for oil derivatives. What Annex 2 of the 1. BImSchV requires for the smoke number, which limits apply and how the values reach the protocol without a scrap of paper.

Read more
Screenshot: the owner's signature on the screen

Guide: photos and the owner's signature right at the appliance

Photograph the rating plate, have the owner sign, done. How photos and signatures belong to a measurement in Kehrwerk and how they end up in the protocol.

Read more
Measurement protocol as a PDF on a phone

The flue gas measurement protocol: what goes in and how the PDF is made

Annex 2 of the 1. BImSchV lists what the certificate for a flue gas measurement must contain at minimum. Here is the list for oil, gas and solid fuels, and how the protocol is made on site with photos and a signature.

Read more
Screenshot: measurement protocol as a PDF

Guide: the measurement protocol as a PDF and the day export as a CSV

One PDF per measurement for the owner and the file, one CSV per day for the office. Where to find both in Kehrwerk, what is in them and how they arrive.

Read more
Wood stove burning in a living room

Measuring solid fuel appliances: wood stoves, log boilers, pellet boilers

Dust, carbon monoxide, wood moisture and 13 percent reference oxygen. What the 1. BImSchV requires for solid fuel installations, when a wood stove is measured and which values belong in the protocol under Annex 2 No. 5.

Read more
Screenshot: calendar with the week's appointments

Guide: plan appointments and import addresses by CSV

Today, Calendar and History show your week at three glances. And one CSV file puts a whole district on the phone in a single step. Here is which columns the app expects.

Read more
Chimney sweep on a roof in Vienna

Flue gas measurement for chimney sweeps in Austria: limits under Art. 15a B-VG

In Austria, an agreement between the federal states under Art. 15a B-VG sets which values are measured when firing installations are inspected and which limits apply. The table for installations under 50 kW, the inspection intervals and how Kehrwerk applies the Austrian rules.

Read more
Screenshot: Business with the country choice

Guide: set Germany, Austria or Switzerland for your business

One setting under Business decides which rules Kehrwerk measures by: 1. BImSchV, Art. 15a B-VG or LRV. What it changes on the appliance, in the measurement and in the protocol.

Read more
Chimney sweep on a roof in the Alps

Combustion inspection in Switzerland: LRV limits for chimney sweeps

In Switzerland, the flue gas loss limit does not follow the output but the burner stage and the commissioning date. What the Ordinance on Air Pollution Control sets for oil and gas, how often installations are checked and how Kehrwerk applies the Swiss rules.

Read more
Screenshot: day list with appointments from the office

Guide: join your business with the activation code

Eight characters from the office, one tap on Join, and the business's appointments are on the phone. What is sent, what stays on the device and how a business gets the office.

Read more
Boiler room with no mobile signal

Flue gas measurement with no signal: why nothing may be lost in the boiler room

No network, no server, no sign-in. How a measurement in the cellar lands safely on the phone, why there is no need for a save button and what happens when the phone gets a signal again.

Read more
Screenshot: day list in Kehrwerk

Kehrwerk at a glance: every feature of the chimney sweep app in one tour

A tour of every screen, from the day list through the measurement to the protocol. What Kehrwerk does, where to find it and which guide helps further.

Read more
Office of a chimney sweep business with the day plan on screen

Running a chimney sweep business digitally: appointments to phones, protocols back to the office

Handing out addresses, collecting protocols, chasing what went missing. How a business with several sweeps plans the day at the computer, gets the measurements back automatically, and what it costs.

Read more
Chimney sweep in a boiler room taking a flue gas measurement

Why Kehrwerk has no save button

The most common complaint about measurement software is not that it is ugly. It is that values you entered are gone. Why Kehrwerk saves every keystroke at once, and what that gives you in the cellar.

Read more